FERRELLGAS INC -- PROPANE -- 6260-01-124-7469
=====================  Product Identification  =====================

Product ID:PROPANE
MSDS Date:06/01/1993
FSC:6260
NIIN:01-124-7469
=== Responsible Party ===
Company Name:FERRELLGAS INC
Address:1 LIBERTY PLZ
City:LIBERTY
State:MO
ZIP:64068-2970
Country:US
Info Phone Num:816-792-1600
Emergency Phone Num:800-424-9300 CHEMTREC
CAGE:0CH06
=== Contractor Identification ===
Company Name:COLEMAN CO,INC
Address:3600 N HYDRAULIC ST
Box:2931
City:WICHITA
State:KS
ZIP:67201-2931
Country:US
Phone:316-832-2710
CAGE:80309
Company Name:FERRELLGAS
Address:1 LIBERTY PLAZA
Box:City:LIBERTY
State:MO
ZIP:64068-2970
Country:US
Phone:816-792-1600; 816-792-6916
CAGE:0CH06

=============  Composition/Information on Ingredients  =============

Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT; 9596

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:CLASSIFIED AS A SIMPLE ASPHYXIANT,
    MINIMAL OXYGEN CONTENT SHOULD BE 19.5% BY VOLUME UNDER NORMAL
    ATMOSPHERIC CONDITIONS. CENTRAL NERVOUS SYSTEM DEPRESSANT. MAY
    CAUSE ANEMIA AND IRREGULAR HEART BEAT. C ONTACT WITH SKIN OR EYE
    MAY CAUSE FROSTBITE.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
    OR GREATER IS LISTED AS A CARCINOGEN BY IARC, NTP OR OSHA.
Effects of Overexposure:DIZZINESS, ANESTHESIA, POSSIBLE RESPIRATORY
    ARREST, IRREGULAR HEART RHYTHM, EYE IRRITATION.
Medical Cond Aggravated by Exposure:CAUTION IS RECOMMENDED FOR
    PERSONNEL WITH PRE-EXISTING CENTRAL NERVOUS SYSTEM OR CHRONIC
    RESPIRATORY DISEASES.

=======================  First Aid Measures  =======================

First Aid:REMOVE TO FRESH AIR. IF NOT BREATHING, ADMINISTER AIR, OXYGEN
    OR ARTIFICIAL RESPIRATION. SKIN-KEEP AFFECTED AREA WARM AND
    SUBMERGE IN LUKEWARM (NOT HOT!) WATER. FLUSH EYES IMMEDIATELY WITH
    WATER.

=====================  Fire Fighting Measures  =====================

Flash Point:-156F,-104C
Autoignition Temp:Autoignition Temp Text:940F
Lower Limits:2.15
Upper Limits:9.60
Extinguishing Media:DRY CHEMICAL, CLASS A-B-C, CARBON DIOZIXDE, WATER
    SPRAY OR HALON.
Fire Fighting Procedures:STOP FLOW OF GAS. WEAR FIRE FIGHTING
    PROTECTIVE EQUIPMENT AND FULL FACE-PIECE SELF-CONTAINED BREATHING
    APPARATUS. COOL FIRE EXPOSED CONTAINERS W/WATER SPRAY.
Unusual Fire/Explosion Hazard:FLAMMABLE LIQUID & GAS UNDER PRESSURE.
    MAY FORM EXPLOSIVE MIXTURES WITH AIR. CONTAINERS EXPOSED TO FIRE OR
    EXCESSIVE HEAT MAY RUPTURE EXPLOSIVELY.

==================  Accidental Release Measures  ==================

Spill Release Procedures:KEEP PUBLIC AWAY. SHUT OFF GAS SUPPLY.
    ELIMINATE SOURCES OF IGNITION. VENTILATE AREA. DISPERSE WITH WATER
    SPRAY. CONTACT BETWEEN SKIN AND LIQUID PROPANE CAN CAUSE FREEZING
    OF TISSUE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CONTAINERS AWAY FROM HEAT SOURCES
    AND STORE CONTAINERS IN UPRIGHT POSITION. CONTAINERS SHOULD NOT BE
    DROPPED.
Other Precautions:CONTAINER TEMPERATURE TEMPERATURE SHOULD NOT EXCEED
    130F (54.4C). CLOSE CONTAINER SERVICE VALVE WHEN NOT IN USE AND
    WHEN EMPTY. INSTALL PROTECTIVE CAP WHEN NOT CONNECTED FOR USE.
    CONTAINERS, EVEN THOS E EMPTIED CAN CONTAIN EXPLOSIVE VAPORS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH OR MSHA APPROVED EQUIPMENT WHEN
    AIRBORN EXPSOURE LIMITS ARE EXCEEDED.
Ventilation:PROVIDE ADEQUATE VENTILATION WHERE PRODUCT IS USED TO MEET
    TLV REQUIREMENTS & KEEP CONCENTRATION IN AIR BELOW 25% OF LEL
Protective Gloves:PLASTIC OR NEOPRENE-COATED CANVAS.
Eye Protection:FACESHIED OR CHEMICAL GOGGLES.
Other Protective Equipment:NOT APPLICABLE.
Work Hygienic Practices:AVOID BREATHING GAS, SECURE AND EVACUATE AREA
    IF GAS IS SMELLED.
Supplemental Safety and Health
SP0-44-94-C-0608. PROPANE CYLINER IS NOT A PART OF THE PACKAGE (NSN) AS
    RECEIVED FROM MFR BUT IS ADDED LATER BY END USER.

==================  Physical/Chemical Properties  ==================

HCC:G2
Boiling Pt:B.P. Text:-44F,-42C
Vapor Pres:208 PSIG
Vapor Density:1.52
Spec Gravity:0.51
Evaporation Rate & Reference:<1 (N-BUTYL ACETATE=1)
Solubility in Water:SLIGHTLY
Appearance and Odor:CLEAR; UNPLEASANT ODOR SIMILAR TO GARLIC (ODORIZED
    BY ETHYL MERCAPTAN).
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, SPARKS, FLAME, BUILD-UP OF STATIC
    ELECTRICITY. PREVENT VAPOR ACCUMULATION.
Hazardous Decomposition Products:CARBON MONOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:CONTROLLED BURNING IN COMPLIANCE WITH APPLICABLE
    CODES AND LAWS. CONTACT SUPPLIER.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.