DYMON INC -- A-120 GLASS/HARD SURFACE & UTILITY CLEANER -- 6850-00N031675
===================== Product Identification =====================
Product ID:A-120 GLASS/HARD SURFACE & UTILITY CLEANER
MSDS Date:06/16/1987
FSC:6850
NIIN:00N031675
=== Responsible Party ===
Company Name:DYMON INC
Address:3401 KANSAS AVE
City:KANSAS CITY
State:KS
ZIP:66106
Country:US
Info Phone Num:800-255-4564
Emergency Phone Num:800-255-4564
CAGE:HO922
=== Contractor Identification ===
Company Name:DYMON INC
Address:3401 KANSAS AVE
Box:6267
City:KANSAS CITY
State:KS
ZIP:66106
Country:US
Phone:800-255-4564
CAGE:HO922
============= Composition/Information on Ingredients =============
Ingred Name:PROPANE, 2-METHYL-; (ISOBUTANE/PROPELLANT)
CAS:75-28-5
RTECS #:TZ4300000
Fraction by Wt: 10%
ACGIH TLV:800 PPM (MFR)
Ingred Name:PROPANE, 2-METHYL-; (ISOPROPONAL FLAMMABLE)
CAS:75-28-5
RTECS #:TZ4300000
Fraction by Wt: 5-15%
OSHA PEL:400 PPM (MFR)
ACGIH TLV:400 PPM (MFR)
Ingred Name:ETHANOL, 2-BUTOXY-, ACETATE; (EGBEA) (ETHYLENE GLYCOL
MONO-BUTYL ETHER)
CAS:112-07-2
RTECS #:KJ8925000
OSHA PEL:50 PPM (MFR)
ACGIH TLV:25 PPM (MFR)
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NASAL IRRIT. ANIMAL STUDIES HAVE
CLEARLY DEMONSTRATED DOSE-RELATED ADVERSE EFTS ON THE CNS,
HEMATOPOIETIC TISSUE, BLOOD, KIDNEYS, & THE LIVER ASSOC W/THE
ADMINISTRATION OF ETHYLENE GLYCOL MONOBUTYL ET HER ACETATE (EGBEA)
(EXTRACTED FROM DHHS(NIOSH) PUB NO. 90-118) .
Explanation of Carcinogenicity:NOT RELEVENT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NASAL IRRITATION.
======================= First Aid Measures =======================
First Aid:INHAL: PROVIDE AIR AND/OR OXYGEN. EYE: IMMEDIATELY FLUSH WITH
POTABLE WATER FOR A MINIMUM OF 15 MIN. SEEK ASSISTANCE FROM MD .
SKIN: FLUSH WITH COPIOUS AMOUNTS OF WATER. CALL MD . INGEST: GET
MD IMMEDIATELY .
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:NONE. EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING
FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
================== Accidental Release Measures ==================
Spill Release Procedures:WASH WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE BELOW 120F.
Other Precautions:AEROSOL MATERIAL UNDER PRESSURE AT 45 PSI. OBSERVE
PRECAUTIONS AND WARNINGS ON LABEL.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST: SATISFACTORY.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NOT NECESSARY.
Work Hygienic Practices:NORMAL.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>179F,>82C
Spec Gravity:0.971 (H2O=1)
Evaporation Rate & Reference:SAME AS WATER
Solubility in Water:100 % SOLUBLE
Appearance and Odor:FOAM
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:HEAT ABOVE 120F.
Hazardous Decomposition Products:CO, CO2.
==================== Disposal Considerations ====================
Waste Disposal Methods:APPROVED LANDFILL. DISPOSAL MUST BE IN
ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.